PRODUCTS AND SERVICES

BIOGAS

02.

Bio-Methane Calorific
Value Control System

DON’T WASTE THE WASTE

BIOGAS UPGRADING PLANT TOTAL SOLUTION

This system is the calorific value control system to meet city gas grid injection(calorific value) from bio-methane and LPG mixing.

Other gases mixing can be applied.

Odorant injection system can be included in this system.

Composed Major Equipment

  • LPG Tank

  • Mixer

  • LPG Pump

  • LPG Vaporizer

  • On-Line GC

  • Flow, Pressure Control System

  • Odorant Injection System

  • Control System (PLC with HMI)

Calorific Value Control System Schematic

This system is the calorific value control system to meet city gas grid injection(calorific value) from bio-methane and LPG mixing.

Other gases mixing can be applied.

Odorant injection system can be included in this system.

Standard Model
Table

Model data

Model Bio-Methane Flow Rate 1)
(N㎥/hr)
Required LPG
Flow Rate 2)
N㎥/hr (kg/hr)
Required Odorant
Flow Rate 3)
(ml/hr)
GBC-200 200 12.41(24.38) 2.5
GBC-3400 400 24.82(48.76) 5.0
GBC-600 600 37.23(73.14) 7.5

1) Applied Composition of Bio-Methane: CH4 (98%), CO2 (2%)

2) Applied LPG Calorific Value: 24,179 kcal/Nm3
Applied Calorific Value of Bio-Methane + LPG Mixture (Product Calorific Value): 10,200 kcal/Nm3

3) Odorant Final Concentration in Product: 10 mg/m3
Odorant Characteristics: THT (70%) + TBM (30%)
Odorant Concentration for Korea Regulation: 4~30 mg/m3

* Calorific Value can be changed by customer requirement.

Fabrication Photo of Uijeongbu Heat Value Control System

Fabrication Photo of Hongcheon Eco Energy Town Heat Value Control System